  1 guard lock safety-door switch/D4SL-N-mounting slide key D4SL-N / D4SL-Nsk10-lk @ world's smallest class 6-contact guard lock safety-door switch D4SL-N> ? wiring time is reduced with two types of wiring methods capable of one-touch attachment and removal. ? a wide variety of built-in switches can be used for various devices. (4-, 5-, and 6-contact models are available) ? key holding force of 1,300 n. ? it is possible to change the key insertion point without detaching the head. ? significantly reduced solenoid current contributes to the reduction of power supply cost. D4SL-Nsk10-lk @ > ? lockout key to prevent workers from becoming trapped inside the hazardous area. ? the vertical d4sl guard lock safety-door switch can be easily mounted on 40 40 mm aluminum frames. ? the plastic material makes the slide key suitable for lightweight doors. terminal block type connector type guard lock safety-door switch slide key be sure to read the ? safety precautions ? on page 22. www.datasheet.co.kr datasheet pdf - http://www..net/
D4SL-N / D4SL-Nsk10-lk @ 2 model number structure model number legend (1) conduit size (2) built-in switch (3) head material (4) door lock and release (5) indicator (6) release key type (7) connection method *1. m20, includes m20-to-1/2-14npt conversion adapter. *2. connector cables are not included with the connector type and are to be purchased separately. D4SL-N @@@@ - @@@ (7) switch (standard type) (6) (5) (4) (3) (2) (1) contact model conduit size 4-contact model 5-contact model 6-contact model 2: g1/2 3: 1/2-14npt *1 4: m20 contact model built-in switch 4-contact model door monitor and lock monitor are connected in series internally. a : 1nc/1no + 1nc/1no b : 1nc/1no + 2nc c : 2nc + 1nc/1no d : 2nc + 2nc door monitor and lock monitor are not connected in series internally. s : 1nc/1no + 1nc/1no t : 1nc/1no + 2nc u : 2nc + 1nc/1no v : 2nc + 2nc 5-contact model e : 2nc/1no + 1nc/1no f : 2nc/1no + 2nc g : 3nc + 1nc/1no h : 3nc + 2nc 6-contact model n : 2nc/1no + 2nc/1no p : 2nc/1no + 3nc q : 3nc + 2nc/1no r : 3nc + 3nc contact model head material 4-contact model f: resin 5-contact model 6-contact model f: resin d: metal common common contact model door lock and release 4-contact model 5-contact model 6-contact model a : mechanical lock/24vdc solenoid release g: 24vdc solenoid lock/mechanical release contact model indicator 4-contact model ? : none 5-contact model 6-contact model d: 24vdc (orange led indicator) contact model release key type 4-contact model ? : standard release key (metal) 5-contact model 6-contact model ? : standard release key (metal) 4: special release key (resin) (note:release keys are provided.) contact model connection method 4-contact model 5-contact model 6-contact model ? : terminal block n: connector *2 common common common common (2) key type ? : no cushion rubber g: cushion rubber s: no cushion rubber, short type (1) operation key type 1: horizontal mounting 2: vertical mounting 3: adjustable mounting (horizontal) D4SL-Nk @@ (1) (2) operation key www.datasheet.co.kr datasheet pdf - http://www..net/
D4SL-N / D4SL-Nsk10-lk @ 3 ordering information list of models note: the recommended models for equipment and machinery being exported to europe are those with an m20 conduit sizes, and for north america, the recommended models are those with a 1/2-14npt conduit sizes. release key type wiring method solenoid voltage/ indicator lock and release type contact configuration (door open/closed detection switch and lock monitor switch contacts) conduit size (see note.) model standard (metal) connector 24vdc (orange) mechanical lock solenoid release 6-contact model insert the built-in switch (n, p, q or r) into the blank @ . g1/2 D4SL-N2 @ fa-dn 1/2-14npt D4SL-N3 @ fa-dn m20 D4SL-N4 @ fa-dn 5-contact model insert the built-in switch (e, f, g or h) into the blank @ . g1/2 D4SL-N2 @ fa-dn 1/2-14npt D4SL-N3 @ fa-dn m20 D4SL-N4 @ fa-dn 24vdc (without indicator) 4-contact model insert the built-in switch (a, b, c, d, s, t, u or v) into the blank @ . g1/2 D4SL-N2 @ fa-n 1/2-14npt D4SL-N3 @ fa-n m20 D4SL-N4 @ fa-n terminal block 24vdc (orange) 6-contact model insert the built-in switch (n, p, q or r) into the blank @ . g1/2 D4SL-N2 @ fa-d 1/2-14npt D4SL-N3 @ fa-d m20 D4SL-N4 @ fa-d 5-contact model insert the built-in switch (e, f, g or h) into the blank @ . g1/2 D4SL-N2 @ fa-d 1/2-14npt D4SL-N3 @ fa-d m20 D4SL-N4 @ fa-d 24vdc (without indicator) 4-contact model insert the built-in switch (a, b, c, d, s, t, u or v) into the blank @ . g1/2 D4SL-N2 @ fa 1/2-14npt D4SL-N3 @ fa m20 D4SL-N4 @ fa connector 24vdc (orange) solenoid lock mechanical release 6-contact model insert the built-in switch (n, p, q or r) into the blank @ . g1/2 D4SL-N2 @ fg-dn 1/2-14npt D4SL-N3 @ fg-dn m20 D4SL-N4 @ fg-dn 5-contact model insert the built-in switch (e, f, g or h) into the blank @ . g1/2 D4SL-N2 @ fg-dn 1/2-14npt D4SL-N3 @ fg-dn m20 D4SL-N4 @ fg-dn 24vdc (without indicator) 4-contact model insert the built-in switch (a, b, c, d, s, t, u or v) into the blank @ . g1/2 D4SL-N2 @ fg-n 1/2-14npt D4SL-N3 @ fg-n m20 D4SL-N4 @ fg-n terminal block 24vdc (orange) 6-contact model insert the built-in switch (n, p, q or r) into the blank @ . g1/2 D4SL-N2 @ fg-d 1/2-14npt D4SL-N3 @ fg-d m20 D4SL-N4 @ fg-d 5-contact model insert the built-in switch (e, f, g or h) into the blank @ . g1/2 D4SL-N2 @ fg-d 1/2-14npt D4SL-N3 @ fg-d m20 D4SL-N4 @ fg-d 24vdc (without indicator) 4-contact model insert the built-in switch (a, b, c, d, s, t, u or v) into the blank @ . g1/2 D4SL-N2 @ fg 1/2-14npt D4SL-N3 @ fg m20 D4SL-N4 @ fg www.datasheet.co.kr datasheet pdf - http://www..net/
D4SL-N / D4SL-Nsk10-lk @ 4 note: the recommended models for equipment and machinery being exported to europe are those with an m20 conduit sizes, and for north america, the recommended models are those with a 1/2-14npt conduit sizes. release key type wiring method solenoid voltage/ indicator lock and release type contact configuration (door open/closed detection switch and lock monitor switch contacts) conduit size (see note.) model special (resin) connector 24vdc (orange) mechanical lock solenoid release 6-contact model insert the built-in switch (n, p, q or r) into the blank @ . g1/2 D4SL-N2 @ fa-d4n 1/2-14npt D4SL-N3 @ fa-d4n m20 D4SL-N4 @ fa-d4n 5-contact model insert the built-in switch (e, f, g or h) into the blank @ . g1/2 D4SL-N2 @ fa-d4n 1/2-14npt D4SL-N3 @ fa-d4n m20 D4SL-N4 @ fa-d4n terminal block 6-contact model insert the built-in switch (n, p, q or r) into the blank @ . g1/2 D4SL-N2 @ fa-d4 1/2-14npt D4SL-N3 @ fa-d4 m20 D4SL-N4 @ fa-d4 5-contact model insert the built-in switch (e, f, g or h) into the blank @ . g1/2 D4SL-N2 @ fa-d4 1/2-14npt D4SL-N3 @ fa-d4 m20 D4SL-N4 @ fa-d4 connector solenoid lock mechanical release 6-contact model insert the built-in switch (n, p, q or r) into the blank @ . g1/2 D4SL-N2 @ fg-d4n 1/2-14npt D4SL-N3 @ fg-d4n m20 D4SL-N4 @ fg-d4n 5-contact model insert the built-in switch (e, f, g or h) into the blank @ . g1/2 D4SL-N2 @ fg-d4n 1/2-14npt D4SL-N3 @ fg-d4n m20 D4SL-N4 @ fg-d4n terminal block 6-contact model insert the built-in switch (n, p, q or r) into the blank @ . g1/2 D4SL-N2 @ fg-d4 1/2-14npt D4SL-N3 @ fg-d4 m20 D4SL-N4 @ fg-d4 5-contact model insert the built-in switch (e, f, g or h) into the blank @ . g1/2 D4SL-N2 @ fg-d4 1/2-14npt D4SL-N3 @ fg-d4 m20 D4SL-N4 @ fg-d4 www.datasheet.co.kr datasheet pdf - http://www..net/
D4SL-N / D4SL-Nsk10-lk @ 5 operation keys connector cables type model horizontal mounting D4SL-Nk1 horizontal mounting (short) D4SL-Nk1s horizontal mounting (cushion rubber) D4SL-Nk1g vertical mounting D4SL-Nk2 vertical mounting (cushion rubber) D4SL-Nk2g adjustable (horizontal) D4SL-Nk3 cable length model 1 m d4sl-cn1 3 m d4sl-cn3 5 m d4sl-cn5 www.datasheet.co.kr datasheet pdf - http://www..net/
D4SL-N / D4SL-Nsk10-lk @ 6 slide key note: 1. the door switch is not included. select the door switch depending on the necessary number of contacts and the conduit size. the contents are provided as a total set, individual contents cannot be ordered separately. 2. perform risk assessment for the equipment in question, configure relay units and other safety circuits, and use properly. * the inner lever for d4gl-sk10/D4SL-Nsk10 that can not be used for other products and applications. applicable door switches D4SL-Nsk10-lk D4SL-Nsk10-lkh type specifications contents model applicable door switch weight: approx. 0.6 kg mechanical durability: 20,000 operations min. slide key: 1 (not yet mounted) D4SL-N mounting plate: 1 door switch special mounting screws: 3 D4SL-Nk1 (operation key): 1 D4SL-Nk1 special mounting screws: 2 lockout keys: 2 lockout key strap: 1 caution labels (stickers): 2 sheets (english and japanese) D4SL-Nsk10-lk D4SL-N weight: approx. 0.1 kg inner lever: 1 d4sl-sk10h * --- weight: approx. 0.7 kg mechanical durability: 20,000 operations min. slide key: 1 (not yet mounted) inner lever: 1 D4SL-N mounting plate: 1 door switch special mounting screws: 3 D4SL-Nk1 (operation key): 1 D4SL-Nk1 special mounting screws: 2 lockout keys: 2 lockout key strap: 1 caution labels (stickers): 2 sheets (english and japanese) D4SL-Nsk10-lkh D4SL-N += d4sl- n d4sl- n sk10-lk += d4sl- n d4sl- n sk10-lkh www.datasheet.co.kr datasheet pdf - http://www..net/
D4SL-N / D4SL-Nsk10-lk @ 7 features the lockout key prevents workers from becoming trapped without using a padlock. note: using leds of D4SL-N enables confirming whether the door is open or closed and locked or unlocked. do not t u rn the key as in the fig u re a b o v e if the slide handle is closed. the slide handle can b e p u lled. the slide handle does not mo v e. if the locko u t key is not mo u nted, the slide handle w ill not mo v e and the door w ill not close. w hen the slide handle is open, the locko u t key can b e p u lled regardless of w hether po w er is b eing s u pplied to the solenoid or not. the slide handle is sec u red at the position sho w n in the fig u re. a w orker holding the locko u t key w ill not b e trapped locked inside the hazardo u s area b y another person. locked (po w er not s u pplied to solenoid) the slide handle is closed. unlocked (po w er s u pplied to solenoid) the slide handle is closed. close door close door the slide handle is open. open door the slide handle is open. open door the slide handle is open. open door door opening to the left. left door the handle-shaped fixt u re makes it easy to u se the door s w itch. attach the s u pplied ca u tion la b els for display. locko u t key cautio n locko u t key g u ard lock safety-door s w itch w ill not b e u nlocked w ith locko u t key. locko u t key may b e damaged b y operating locko u t key w hen the door is closed. al w ays carry locko u t key w hen entering the hazardo u s area. n o. 7467139-3a www.datasheet.co.kr datasheet pdf - http://www..net/
D4SL-N / D4SL-Nsk10-lk @ 8 structure and nomenclature structure can b e mo u nted from fo u r directions. t w o operation key holes the s w itch has a release key on the b ack of the s w itch as w ell. the s w itch has an indicator on the b ack of the s w itch as w ell. can b e mo u nted from fo u r directions. t w o operation key holes the s w itch has a release key on the b ack of the s w itch as w ell. the s w itch has an indicator on the b ack of the s w itch as w ell. e1 ( + ) e2 ( ? ) 11 21 33 9 10 41 51 63 42 52 64 ora n ge 1 2 3 4 5 6 7 8 12 22 34 for D4SL-N @ n @@ -d @ note: numbers inside the boxes are terminal numbers printed on the product. d4sl- @@@@ -d @ terminal block type D4SL-N @@@@ -d @ n connector type 45610 3 2 1 n otched side is n o. 1 13 579 10 6 4 28 connector/terminal terminal arrengement www.datasheet.co.kr datasheet pdf - http://www..net/
D4SL-N / D4SL-Nsk10-lk @ 9 operating cycle examples for standard models D4SL-N @@@ a- @ (mechanical lock models) D4SL-N @@@ g- @ (solenoid lock models) door open/closed detection and lock monitor contacts: can be used in safety circuits because of the direct opening mechanisms. door open/closed detection contact: can be used to confirm whether the key is inserted and to monitor the open/closed status of a door. lock monitor contact: can be used to confirm whether power is supplied to the solenoid and to monitor whether or not a door can be opened or closed. note: 1. the door open/closed detection and lock monitor contact configuration depends on the model. 2. if a current is detected in the solenoid lock model (built-in switches; n, p, q, r), before the door is closed, the door will r emain unlocked. be sure to supply power to the solenoid after the door is closed. door condition condition 1 condition 2 condition 3 turning the special release key terminal no. and contact no. function door open. the door will lock when the door closes. door closed. the door is locked. door closed. the door can be opened. door closed. no power is supplied to the solenoid. the door is unlocked manually. solenoid on door open/closed detection and lock monitor contacts door open/closed detection contact door open/closed detection contact lock monitor contact lock monitor contact door condition even when the door is closed, it does not lock until power is supplied to the solenoid. door closed. the door is locked. door closed. the door can be opened. terminal no. and contact no. function solenoid on door open/closed detection and lock monitor contacts door open/closed detection contact door open/closed detection contact lock monitor contact lock monitor contact ret u rn to condition 1 e1- 10 e2 9 42- 1 11 (nc) 2 52- 3 21 (nc) 4 21- 4 22 (nc) 3 31- 6 32 (nc) 5 33- 6 34 (no) 5 41- 2 42 (nc) 1 61- 8 62 (nc) 7 63- 8 64 (no) 7 the shaded areas indicate the contact is closed and power is supplied to the solenoid. e1- 10 e2 9 42- 1 11 (nc) 2 52- 3 21 (nc) 4 21- 4 22 (nc) 3 31- 6 32 (nc) 5 33- 6 34 (no) 5 41- 2 42 (nc) 1 61- 8 62 (nc) 7 63- 8 64 (no) 7 www.datasheet.co.kr datasheet pdf - http://www..net/
D4SL-N / D4SL-Nsk10-lk @ 10 specifications standards and ec directives conforms to the following ec directives: ? machinery directive ? low voltage directive ? emc directive ? en10 88 ? en60204-1 ? gs-et-19 certified standards *1. only certain models have been certified. certified standard ratings tv (en60947-5-1) note: use a 4 a fuse that conforms to iec60127 as a short-circuit protection device. this fuse is not included with the switch. *1. 11-42, 21-52, 21-22 *2. other terminals ul/csa (ul508, csa c22.2 no.14) c150 r150 solenoid coil characteristics * a starting current is applied to the solenoid for approx. 10 seconds. after this, the internal circuit switches to a constant current. indicator certification body standard file no. tv sd en60947-5-1 (certified direct opening) consult your omron representative for details. ul ul50 8 , csa c22.2 no.14 cqc (ccc) gb1404 8 .5 pending kosha *1 en60947-5-1 consult your omron representative for details. utilization category ac-15 dc-13 rated operating current (ie) 1.5 a *1 1 a *2 0.22 a rated operating current (ue) 120 v 125 v rated voltage carry current current (a) volt-amperes (va) make break make break 120 vac 2.5 a 15 1.5 1, 8 00 1 8 0 rated voltage carry current current (a) volt-amperes (va) make break make break 125 vdc 1.0 a 0.22 0.22 2 8 2 8 item 24 vdc rated operating voltage (100% ed) 24 vdc current consumption * power on: 6-contact type approx. 6.4 w at 0.26 a 4-contact/5-contact type approx. 4. 8 w at 0.2 a constant: approx. 2.6 w (average) at 0.2 a (max.) insulation class e (to 120 c) item led type rated voltage 24 vdc current consumption approx.10 ma color (led) orange + 10% ? 15% www.datasheet.co.kr datasheet pdf - http://www..net/
D4SL-N / D4SL-Nsk10-lk @ 11 characteristics note: 1. the above values are initial values. 2. the switch contacts can be used with either standard loads or microloads. once the contacts have been used to switch a load, however, they cannot be used to switch smaller loads. the contact surfaces will become rough once they have been used and contact reliability for smaller loads may be reduced. *1. the degree of protection is tested using the method specified by the standard (en60947-5-1). confirm that sealing properties are sufficient for the operating conditions and environment beforehand. although the switch box is protected from dust, oil or water penetration, do not use the d4sl in places where cutting chips, oi l, water or chemicals may enter through the key hole on the head, otherwise switch damage or malfunctioning may occur. *2. the durability is for an ambient temperature of 5 to 35 c and an ambient humidity of 40% to 70%. for more details, consult your omron representative. *3. do not pass the 1 a, 125 vac load through more than 3 circuits. *4. these figures are minimum requirements for safe operation. *5. this figure is based on the gs-et-19 evaluation method. *6. this value will vary with the switching frequency, environment, and reliability level. confirm that correct operation is possible with the actual load beforehand. degree of protection *1 ip67 (en60947-5-1) durability *2 mechanical 1,000,000 operations min. electrical 150,000 operations min. (1 a resistance at 125 vac) *3 operating speed 0.05 to 1 m/s operating frequency 5 operations minute max. direct opening force *4 60 n min. (en60947-5-1) direct opening travel *4 15 mm min. (en60947-5-1) holding force *5 1,300 n min. contact resistance 200 m max. minimum applicable load *6 1 ma resistive load at 5 vdc (n-level reference value) rated insulation voltage (ui) 150 v (en60947-5-1) rated frequency 50/60 hz protection against electric shock class ii (double insulation) pollution degree (operating environment) 3 (en60947-5-1) impulse withstand voltage (en60947-5-1) between terminals of same polarity 1.5 kv between terminals of different polarity 1.5 kv between other terminals and non-current carrying metallic parts 2.5 kv insulation resistance 100 min. (at 500 vdc) vibration resistance malfunction 10 to 55 hz, 0.35 mm single amplitude shock resistance malfunction 8 0 m/s 2 min. destruction 1,000 m/s 2 min. conditional short-circuit current 100 a (en60947-5-1) conventional free air thermal current (ith) 2.5a (11-42, 21-52, 21-22) 1a (others) ambient operating temperature ? 10 to 55 c (with no icing) ambient operations humidity 95% max. weight head: resin approx. 290 g (connector model) approx. 330 g (terminal block model) head: metal approx. 370 g (connector model) approx. 410 g (terminal block model) www.datasheet.co.kr datasheet pdf - http://www..net/
D4SL-N / D4SL-Nsk10-lk @ 12 connection internal circuit diagram without indicator with indicator circuit connection example ? direct opening contacts used as safety-circuit input are indicated with the mark. ? do not switch circuits for three or more standard loads at the same time. doing so may adversely affect insulation performance. ? dc solenoids have polarity. (e1: positive, e2: negative) confirm terminal polarity before wiring. connection example for D4SL-N @ af @ - @ terminals 12-41 are connected internally. connection example for D4SL-N @ ef @ -d @ terminals 12-41 are connected internally. connection example for D4SL-N @ sf @ - @ connection example for D4SL-N @ nf @ -d @ terminals 12-41 and 22-51 are connected internally. d d 24 v dc e1 ( + ) e2 ( ? ) z d control circ u it d d 24 v dc r led e1 ( + ) e2 ( ? ) z d control circ u it e1 ( + ) e2 ( ? ) to control circ u it 11 33 lock monitor s w itch 9 10 41 63 42 64 1 2 3 4 5 6 7 8 12 34 to control circ u it to safety circ u it ( n ot u se) ( n ot u se) door open/ closed detection s w itch e1 ( + ) e2 ( ? ) to safety circ u it to control circ u it 11 21 33 lock monitor s w itch 9 10 led 41 63 42 22 64 1 2 3 4 5 6 7 8 12 34 to control circ u it to safety circ u it door open/ closed detection s w itch e1 ( + ) e2 ( ? ) to control circ u it 21 41 33 lock monitor s w itch 9 10 63 42 22 64 1 2 3 4 5 6 7 8 34 to control circ u it to safety circ u it door open/ closed detection s w itch a n d e1 ( + ) e2 ( ? ) to safety circ u it to control circ u it 11 21 33 lock monitor s w itch 9 10 led 41 51 63 42 52 64 1 2 3 4 5 6 7 8 12 22 34 to control circ u it to safety circ u it door open/ closed detection s w itch www.datasheet.co.kr datasheet pdf - http://www..net/
D4SL-N / D4SL-Nsk10-lk @ 13 contact form indicates conditions where the key is inserted and the lock is applied. model contact (door open/ closed detection and lock monitor) contact form operating pattern remarks lock monitor door open/ closed detection D4SL-N @ a @@ - @ 1nc/1no+ 1nc/1no only nc contact 11-12 has a certified direct opening mechanism. the terminals 42-11, 34-33, and 64-63 can be used as unlike poles. D4SL-N @ b @@ - @ 1nc/1no+2nc only nc contact 11-12 has a certified direct opening mechanism. the terminals 42-11, 34-33, and 62-61 can be used as unlike poles. D4SL-N @ c @@ - @ 2nc+1nc/1no only nc contact 11-12 and 31- 32 has a certified direct opening mechanism. the terminals 42-11, 32-31, and 64-63 can be used as unlike poles. D4SL-N @ d @@ - @ 2nc+2nc only nc contact 11-12 and 31- 32 has a certified direct opening mechanism. the terminals 42-11, 32-31, and 62-61 can be used as unlike poles. D4SL-N @ s @@ - @ 1nc/1no+ 1nc/1no only nc contact 21-22 has a certified direct opening mechanism. the terminals 42-41, 22-21, 34- 33, and 64-63 can be used as unlike poles. D4SL-N @ t @@ - @ 1nc/1no+2nc only nc contact 21-22 has a certified direct opening mechanism. the terminals 42-11, 22-21, 34- 33, and 62-61 can be used as unlike poles. D4SL-N @ u @@ - @ 2nc+1nc/1no only nc contact 21-22 and 31- 32 has a certified direct opening mechanism. the terminals 42-11, 22-21, 32- 31, and 64-63 can be used as unlike poles. D4SL-N @ v @@ - @ 2nc+2nc only nc contact 21-22 and 31- 32 has a certified direct opening mechanism. the terminals 42-11, 22-21, 32- 31, and 62-61 can be used as unlike poles. 42 64 63 41 12 door open/closed detection lock monitor 11 34 33 on stroke 42-11 34-33 64-63 operation key insertion completion position extraction completion position lock position 42 62 61 41 12 11 34 33 door open/closed detection lock monitor on stroke 42-11 34-33 62-61 operation key insertion completion position extraction completion position lock position 42 64 63 41 12 11 32 31 door open/closed detection lock monitor on stroke 42-11 32-31 64-63 operation key insertion completion position extraction completion position lock position 42 62 61 41 12 11 31 32 door open/closed detection lock monitor on stroke 42-11 32-31 62-61 operation key insertion completion position extraction completion position lock position 42 64 63 41 34 33 21 22 door open/closed detection lock monitor on stroke 42-41 22-21 34-33 64-63 operation key insertion completion position extraction completion position lock position 42 62 61 41 34 33 21 22 door open/closed detection lock monitor on stroke 42-41 22-21 34-33 62-61 operation key insertion completion position extraction completion position lock position 42 64 63 41 32 31 21 22 door open/closed detection lock monitor on stroke 42-41 22-21 32-31 64-63 operation key insertion completion position extraction completion position lock position 42 62 61 41 32 31 21 22 door open/closed detection lock monitor on stroke 42-41 22-21 32-31 62-61 operation key insertion completion position extraction completion position lock position www.datasheet.co.kr datasheet pdf - http://www..net/
D4SL-N / D4SL-Nsk10-lk @ 14 model contact (door open/ closed detection and lock monitor) contact form operating pattern remarks lock monitor door open/ closed detection D4SL-N @ e @@ - @ 2nc/1no+ 1nc/1no only nc contact 11-12 and 21- 22 has a certified direct opening mechanism. the terminals 42-11, 22-21, 34- 33, and 64-63 can be used as unlike poles. D4SL-N @ f @@ - @ 2nc/1no+2nc only nc contact 11-12 and 21- 22 has a certified direct opening mechanism. the terminals 42-11, 22-21, 34- 33, and 62-61 can be used as unlike poles. D4SL-N @ g @@ - @ 3nc+1nc/1no only nc contact 11-12 ,21-22 and 31-32 has a certified direct opening mechanism. the terminals 42-11, 22-21, 32- 31, and 64-63 can be used as unlike poles. D4SL-N @ h @@ - @ 3nc+2nc only nc contact 11-12 ,21-22 and 31-32 has a certified direct opening mechanism. the terminals 42-11, 22-21, 32- 31, and 62-61 can be used as unlike poles. D4SL-N @ n @@ - @ 2nc/1no+ 2nc/1no only nc contact 11-12 and 21- 22 has a certified direct opening mechanism. the terminals 42-11, 52-21, 34- 33, and 64-63 can be used as unlike poles. D4SL-N @ p @@ - @ 2nc/1no+3nc only nc contact 11-12 and 21- 22 has a certified direct opening mechanism. the terminals 42-11, 52-21, 34- 33, and 62-61 can be used as unlike poles. D4SL-N @ q @@ - @ 3nc+2nc/1no only nc contact 11-12 ,21-22 and 31-32 has a certified direct opening mechanism. the terminals 42-11, 52-21, 32- 31, and 64-63 can be used as unlike poles. D4SL-N @ r @@ - @ 3nc+3nc only nc contact 11-12 ,21-22 and 31-32 has a certified direct opening mechanism. the terminals 42-11, 52-21, 32- 31, and 62-61 can be used as unlike poles. 42 64 63 41 12 11 34 33 21 22 door open/closed detection lock monitor on stroke 42-11 22-21 34-33 64-63 operation key insertion completion position extraction completion position lock position 42 62 61 41 12 11 34 33 21 22 door open/closed detection lock monitor on stroke 42-11 22-21 34-33 62-61 operation key insertion completion position extraction completion position lock position 42 64 63 41 12 11 32 31 21 22 door open/closed detection lock monitor on stroke 42-11 22-21 32-31 64-63 operation key insertion completion position extraction completion position lock position 42 62 61 41 12 11 21 22 31 32 door open/closed detection lock monitor on stroke 42-11 32-31 22-21 62-61 operation key insertion completion position extraction completion position lock position 42 52 51 64 63 41 12 door open/closed detection lock monitor 11 34 33 21 22 on stroke 42-11 52-21 34-33 64-63 operation key insertion completion position extraction completion position lock position 42 52 51 62 61 41 12 11 34 33 21 22 door open/closed detection lock monitor on stroke 42-11 52-21 34-33 62-61 operation key insertion completion position extraction completion position lock position 42 52 51 64 63 41 12 11 32 31 21 22 door open/closed detection lock monitor on stroke 42-11 52-21 32-31 64-63 operation key insertion completion position extraction completion position lock position 42 52 51 62 61 41 12 11 21 22 31 32 door open/closed detection lock monitor on stroke 42-11 52-21 32-31 62-61 operation key insertion completion position extraction completion position lock position www.datasheet.co.kr datasheet pdf - http://www..net/
D4SL-N / D4SL-Nsk10-lk @ 15 dimensions and oper ating characteristics (unit:mm) switches note: unless otherwise specified, a tolerance of 0.4 mm applies to all dimensions. 22 0.2 4 (10.85 ) (8) (1) 26 dia. a release key 4.5 dia. (depth: 1.6) front-side mo unting t w o, 4.3 dia. mounting hole led indicators 22 0.2 10 b label 4.5 dia. (depth: 1.6) side mo unting three, 4.3 dia. mounting hole 29.2 29.2 pre-tra v el distance 9 head cap operation key one, cond uit conduit cap t w o, co v er mounting scre w 26.3 (10.85) b-b a-a release key 4.5 dia. (depth: 1.6) led indicators 26.3 4.5 dia. (depth: 1.6) spacers 41.7 0.2 (62.75) (73.5) a 41.7 0.2 (155) 41.7 0.2 39 112.1 0.8 (73.5) 31.5 42.9 (62.75) b 39 38.7 0.2 37 41.7 0.2 38.5 D4SL-N @@@@-@ n (connector type) model operating characteristics D4SL-N @@@@ - @ n key insertion force key extraction force 15 n max. 30 n max. pre-travel distance 15 mm max. movement before being locked 3 mm min. operation key b-b a-a 22 0.2 4 (10.85 ) 26 dia. (1) (8) 4.5 dia. (depth: 1.6) 22 0.2 10 29.2 29.2 pre-tra v el distance 9 26.3 (10.85) 26.3 release key spacers front-side mo unting t w o, 4.3 dia. mounting hole b b 4.5 dia. (depth: 1.6) led indicators 4.5 dia. (depth: 1.6) release key side mounting three, 4.3 dia. mounting hole 4.5 dia. (depth: 1.6) 39 37 41.7 0.2 38.5 38.7 0.2 led indicators 41.7 0.2 head cap one, cond uit conduit cap t w o, co v er mounting scre w (179.9) 41.7 0.2 a a 137 0.8 (73.5) 31.5 42.9 (62.75) 39 41.7 0.2 (62.75) (73.5) D4SL-N @@@@-@ (terminal block type) model operating characteristics D4SL-N @@@@ - @ key insertion force key extraction force 15 n max. 30 n max. pre-travel distance 15 mm max. movement before being locked 3 mm min. www.datasheet.co.kr datasheet pdf - http://www..net/
D4SL-N / D4SL-Nsk10-lk @ 16 operation key note: unless otherwise specified, a tolerance of 0.4 mm applies to all dimensions. connector cables 22.7 2 21.5 7 7 4.3 fo u r, r2.15 35 15 29 28 D4SL-Nk1 22.7 2 19.5 13 fo u r, r2.15 7 7 4.3 35 15 29 D4SL-Nk1s 22.7 t w o, 9 dia. t w o, 4.3 dia. mo u nting r ubb er 2 21.5 35 20 (5.2) 12 29 28 D4SL-Nk1g 22.7 2 15.6 fo u r, r2.15 35 7 7 14.5 4.3 8 15 29 D4SL-Nk2 22.7 17.2 35 2 14.5 8 t w o, 9 dia. t w o, 4.3 dia. mo u nting r ubb er 20 12 29 D4SL-Nk2g 29 22.7 30 15 4.5 dia. 8 dia. 9 dia. 40 angle adj u stment b olt 56 20 17.7 4 D4SL-Nk3 connector ca b le a w g22, 10 cond u ctors * * all 10 lead w ires laid b are. connector pin n o. 10 9 8 7 6 5 4 3 2 1 (30) l 40 (150) (5) d4sl-cn @ model l size d4sl-cn1 1 m d4sl-cn3 3 m d4sl-cn5 5 m connector no. lead wire color connector no. lead wire color 1 black 6 green/white 2 black/white 7 yellow 3red 8 yellow/white 4red/white 9 brown 5 green 10 brown/white www.datasheet.co.kr datasheet pdf - http://www..net/
D4SL-N / D4SL-Nsk10-lk @ 17 slide key D4SL-Nsk10-lk D4SL-Nsk10-lkh slide lock slide free slide lock slide free 4040 107 (147) 50 (64) 17 11.5 17 11.5 fo u r, m6 mo u nting holes d4sl- n k1s operation key g u ard lock safety-door s w itch d4sl- n three, m4 t w o, m6 mo u nting holes (32.5) 38.7 (35) (26.8) (35) (20) (56.5) (76.2) (330) (314) 12.5 10 (112) (232.2) (81.8) (30.2) (90.4) (19.5) (71.8) 19.1 8 slide b ase shot b olt locko u t key open door close door g u ide s w itch b ase a a b b 12.5 22 20 11.6 4 4 cross-sectional v ie w b-b cross-sectional v ie w a-a (bet w een slide key) 15 + 10 ? 5 slide lock slide free slide lock slide free slide b ase d4sl- n k1s operation key g u ard lock safety-door s w itch d4sl- n @@@@ - @@ n g u ard lock safety-door s w itch d4sl- n @@@@ - @@ t w o, m6 mo u nting holes (323) al u min u m frame 40 40 12.5 10 (147) (35) (121) 50 (64) 90.4 (19.5) 19.1 8 fo u r, m6 mo u nting holes shot b olt locko u t key three, m4 g u ide inner le v er s w itch b ase b 12.5 22 20 11.6 4 4 cross-sectional v ie w b-b cross-sectional v ie w a-a 107 (35) (20) (bet w een slide key) 17 11.5 17 40 (26.8) (39.2) 11.5 (32.5) 38.7 (56.5) (76.2) 330 a b 15 + 10 ? 5 a (81.8) (71.8) (115) (78) 40 dia. 12 dia. (241.2) open door close door www.datasheet.co.kr datasheet pdf - http://www..net/
D4SL-N / D4SL-Nsk10-lk @ 18 operation key mounting 59 min. 61.5 max. key insertion position v ertical insertion radi u s r > = 200 center tolerance of key hole: 0.8 59 min. 61.5 max. (15) key insertion position horizontal insertion radi u s r > = 180 center tolerance of key hole: 0.8 (37) (37) 31.5 D4SL-N+D4SL-Nk1 with front-inserted operation key with top-inserted operation key (15) horizontal insertion radi u s r > = 180 60.5 min. 63 max. key insertion position center tolerance of key hole: 0.8 9 center tolerance of key hole: 0.8 60.5 min. 63 max. key insertion position v ertical insertion radi u s r > = 200 (38.5) (38.5) v ertical insertion radi u s r > = 200 center tolerance of key hole: 0.8 50.5 min. 53 max. (15) key insertion position 50.5 min. 53 max. key insertion position horizontal insertion radi u s r > = 180 center tolerance of key hole: 0.8 31.5 (37) (37) (15) horizontal insertion radi u s r > = 180 52 min. 54.5 max. key insertion position center tolerance of key hole: 0.8 9 center tolerance of key hole: 0.8 52 min. 54.5 max. key insertion position v ertical insertion radi u s r > = 200 (38.5) (38.5) D4SL-N+D4SL-Nk1s with front-inserted operation key with top-inserted operation key v ertical insertion radi u s r > = 140 center tolerance of key hole: 0.8 59 min. 61.5 max. key insertion position 59 min. 61.5max. key insertion position horizontal insertion radi u s pitch 12 mm r > = 120 pitch 20 mm r > = 170 center tolerance of key hole: 0.8 (pitch 12 mm) (pitch 20 mm) (37) 31.5 (28.9) (37) 60.5 min. 63 max. key insertion position center tolerance of key hole: 0.8 (pitch 12 mm) (pitch 20 mm) horizontal insertion radi u s pitch 12 mm r > = 120 pitch 20 mm r > = 170 (6.4) 9 center tolerance of key hole: 0.8 v ertical insertion radi u s r > = 140 60.5 min. 63 max. key insertion position (38.5) (38.5) D4SL-N+D4SL-Nk1g with front-inserted operation key with top-inserted operation key www.datasheet.co.kr datasheet pdf - http://www..net/
D4SL-N / D4SL-Nsk10-lk @ 19 53.1 min. 55.6 max key insertion position v ertical insertion radi u s r > = 200 center tolerance of key hole: 0.8 53.1 min. 55.6 max. (15) key insertion position horizontal insertion radi u s r > = 180 center tolerance of key hole: 0.8 (37) 31.5 (39.5) (37) (38.5) horizontal insertion radi u s r > = 180 54.6 min. 57.1 max. key insertion position center tolerance of key hole: 0.8 9 center tolerance of key hole: 0.8 54.6 min. 57.1 max. key insertion position v ertical insertion radi u s r > = 200 (15) (17) (38.5) D4SL-N+d4sl-k2 with front-inserted operation key with top-inserted operation key v ertical insertion radi u s r > = 140 center tolerance of key hole: 0.8 54.7 min. 57.2 max. key insertion position 54.7 min. 57.2 max. key insertion position horizontal insertion radi u s pitch 12 mm r > = 120 pitch 20 mm r > = 170 center tolerance of key hole: 0.8 (pitch 12 mm) (pitch 20 mm) (37) (37) 31.5 (39.5) center tolerance of key hole: 0.8 (pitch 12 mm) (pitch 20 mm) horizontal insertion radi u s pitch 12 mm r > = 120 pitch 20 mm r > = 170 56.2 min. 58.7 max. key insertion position 9 (21.5) center tolerance of key hole: 0.8 v ertical insertion radi u s r > = 140 56.2 min. 58.7 max. key insertion position (38.5) (38.5) D4SL-N+D4SL-Nk2g with front-inserted operation key with top-inserted operation key 55.2 min. 55.7 max. key insertion position v ertical insertion radi u s r > = 200 center tolerance of key hole: 0.8 55.2 min. 55.7 max. key insertion position horizontal insertion radi u s r > = 50 center tolerance of key hole: 0.8 (37) (37) (40 0.15 ) 31.5 horizontal insertion radi u s r > = 50 56.7 min. 59.2 max. key insertion position center tolerance of key hole: 0.8 (40 0.15 ) (9) center tolerance of key hole: 0.8 v ertical insertion radi u s r > = 200 56.7 min. 59.2 max. key insertion position (38.5) (38.5) D4SL-N+D4SL-Nk3 with front-inserted operation key with top-inserted operation key www.datasheet.co.kr datasheet pdf - http://www..net/
D4SL-N / D4SL-Nsk10-lk @ 20 application example g9sa-321-t @ (24vac/vdc) +D4SL-N @ r @ a- @ (mechanical lock type) / manual reset 9 1 2 3 4 5 6 7 8 10 th sa s2 ope n s4 km1 km2 42 41 12 11 to plc to plc a1 a2 t11 t12 t31 t32 13 23 33 43 53 61 1 2 3 4 5 6 jp k3 3 4 2 5 k4 k1 k2 k1 k1 pe t21 t23 t22 ab 14 24 34 km1 km2 km1 km2 m 44 54 62 k2 k2 6 k3 1 a b offdelay timer control circ u it k4 a b (operation instr u ction) feed b ack loop stop signal g u ard lock release signal km1 km2 s3 motor controller s1 k1 and k2 ( n c) k1 and k2 ( n o) k3 and k4 ( n c) k3 and k4 ( n o) km1 and km2 ( n c) km1 and km2 ( n o) operation instr u ction motor rotation off-delay time g u ard can b e opened reset s w itch s3 stop signal lock release signal s4 limit s w itch s1 g u ard lock safety-door s w itch s2 g u ard opens note: 1. the above circuit diagram is for category 3. 2. numbers inside the boxes are terminal numbers printed on the product. s1: safety limit switch with direct opening mechanism (d4b-n, d4n or d4f) s2: D4SL-N s3: reset switch s4: lock release switch km1 and km2: magnetic contactor m: 3-phase motor timing chart www.datasheet.co.kr datasheet pdf - http://www..net/
D4SL-N / D4SL-Nsk10-lk @ 21 g9sa-301 (24 vac/vdc)+D4SL-N @ q @ g- @ (solenoid lock type) / auto-reset th sa to plc to plc 1 2 3 4 5 6 7 8 10 9 a1 a2 t11 t12 k1 k1 pe t21 t23 t22 k2 k2 6 a b 1 2 3 4 5 6 jp 13 t32 t31 23 33 41 2 5 3 1 k1 k2 4 a b control circ u it 14 24 34 42 ab feed b ack loop km1 km2 km1 km2 m (operation instr u ction) motor controller lock signal operation signal km1 km2 41 42 12 11 s2 s1 ope n 12 11 limit s w itch s1 g u ard lock safety-door s w itch s2 k1 and k2 ( n o) k1 and k2 ( n c) km1 and km2 ( n c) km1 and km2 ( n o) g u ard opens operation signal lock signal s1: safety limit switch with direct opening mechanism (d4b-n, d4n or d4f) s2: D4SL-N km1 and km2: magnetic contactor m: 3-phase motor timing chart note: 1. this circuit diagram is for category 4. 2. the lock can be released at any time. therefore, do not use a model with a solenoid lock in applications where the operator may be exposed to danger when the guard opens. use a model with a mechanical lock. 3. numbers inside the boxes are terminal numbers printed on the product. www.datasheet.co.kr datasheet pdf - http://www..net/
D4SL-N / D4SL-Nsk10-lk @ 22 safety precautions be sure to read the precautions for all safety door switches in the website at:http://www.ia.omron.com/. D4SL-N D4SL-Nsk10-lk @ D4SL-N operating environment do not use the switch submersed in oil or water or in locations continuously subject to splashes of oil or water. doing so may result in oil or water entering the switch. (the ip67 degree of protection of the switch specifies the amount of water penetration after the switch is submerged in water for a certain period of time.) wiring ? do not switch circuits for three or more standard loads (125 vac, 1a). doing so may adversely affect insulation performance. ? do not allow the load current to exceed the rated value. for metal connector, use a connector with the screw length of 9 mm or less. otherwise it may result in electric shock. ? do not use metallic conduits. in the event of damage to the conduit opening, this may cause seal failure and may result in electric shock. ? do not use a metal connector for a 1/2-14npt connector. in the event of damage to the conversion adapter, this may cause seal failure and may result in electric shock. ? always attach the cover after completing wiring and before using the switch. do not supply power when the cover is not attached. electric shock may occur if the switch is used without the cover attached. ? when using the terminal block type, make sure that foreign material does not adhere to the terminal block board. otherwise a short circuit may occur between terminals and safety functions may fail to work properly. installation ? make sure the switch is mounted securely to prevent it from falling off. otherwise injury may result. ? do not use a switch as a stopper. be sure to install a stopper as shown in the following illustration so that the operation key does not touch the head. do not subject the switch to a shock that exceeds the switch's shock resistance of 1,000 m/s 2 . indicates an imminently hazardous situation which, if not avoided, is likely to result in serious injury or may result in death. additionally there may be severe property damage. indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury or in property damage. precautions for safe use supplementary comments on what to do or avoid doing, to use the product safely. precautions for correct use supplementary comments on what to do or avoid doing, to prevent failure to operate, malfunction or undesirable effect on product performance. danger injury may occasionally occur. always check to make sure that the safety functions operate correctly before using the machine. the safety functions may not operate correctly because of wiring mistakes, setting mistakes, or switch malfunction, causing some machines to continue operating in situations where they should be stopped. caution injury may occasionally occur. when the switch function is damaged, some machines may continue operating in situations where they should be stopped. do not impose a force exceeding the key holding force. always provide a lock separate from the switch, attach a warning seal to avoid excessive force applied to the switch, or provide an indicator lamp to show the locked/unlocked status of the door. do not use this product mounted so that it slides vertically. this may cause malfunction, resulting in personal injury. do not insert the operation key with the door open. devices may start to operate, resulting in injury. danger caution precautions for safe use stopper head operation key s w itch www.datasheet.co.kr datasheet pdf - http://www..net/
D4SL-N / D4SL-Nsk10-lk @ 23 D4SL-Nsk10-lk @ ? do not drop the product. doing so may prevent the product from functioning to full capacity. ? mount the product securely to prevent it from falling. otherwise, injury may occur. ? do not attempt to disassemble or modify the switch. doing so may cause the switch to malfunction. ? make sure that the gap between the shot bolt and the guide is 0.5 mm. otherwise, excessive wear or damage may cause malfunction. ? to ensure safety, do not operate the switch with anything other than the slide key unit. ? your hand may be injured by being pinched between the operation key and switch when closing the door with your hand on the product. ? be careful to avoid pinching your hand when operating the slide handle. ? do not impose a force of exceeding 1 n ? m when operating the lockout key. otherwise, the product may be damaged and may not operate properly. to prevent damage, attach the supplied labels for display near the product. ? do not force the slide handle to move when the lockout key is not inserted. doing so may damage the product and make operation impossible. ? do not force the slide handle to move when the door is locked. doing so may damage the product and make operation impossible. ? do not close the door with the shot bolt removed. doing so may damage the product and make operation impossible. ? turn the lockout key to the "slide lock" position and remove it when opening the door to prevent a third party from operating the slide handle. ? the durability of the switch varies considerably depending on the switching conditions. always confirm the usage conditions by using the switch in an actual application, and use the switch only for the number of switching operations given in the performance specifications. ? the user must not maintain or repair equipment incorporating the switch. contact the manufacturer of the equipment for any maintenance or repairs required. ? refer to the D4SL-N guard lock safety-door switch instruction sheet about storage conditions, ambient conditions, switch details, and handling methods. ? do not apply excessive force in the direction of the slide. this may damage the product and cause it to malfunction. ? do not force the switch or cable. this may damage the product. the cable should be fixed at a point separate from the switch. D4SL-N solenoid lock models ? be sure to supply power to the solenoid after the door is closed (after the operation key is inserted). ? the solenoid lock locks the door only when power is supplied to the solenoid. therefore, the door will be unlocked if the power supply to the solenoid stops. therefore, do not use solenoid lock models for machines that may be operating and dangerous even after the machine stops operating. release key ? the release key is used to unlock the switch in case of emergency or if the power supply to the switch stops. ? if the release key setting is changed from lock to unlock, the lock will be released and the safety door can be opened (mechanical lock models only). ?@ ? after setting the release key to unlock to, for example, perform maintenance, be sure to return it to lock setting before resuming operation. ? the release key is set in the unlock position at the factory for the D4SL-N @@@ a and to the lock position for the D4SL-N @@@ g. ? in the unlock position, even when the door of large machines or stamping machines is closed during preliminary adjustment, the door will remain unlocked and the machines will not be activated. ? do not use the release key to start or stop machines. ? the auxiliary lock must be released only by authorized personnel. ? do not impose a force exceeding 0.2 n ? m on the release key screws. the release key may be damaged and may not operate properly. ? to prevent the release key from being used by unauthorized personnel, set it to lock and seal it with sealing wax. mounting covers ? confirm that the seal rubber has no defects before use. if the seal rubber is displaced or raised, or has foreign particles adhered to it, the sealing capability of the seal rubber will be adversely affected. slide lock slide free precautions for correct use u n lock lock u n lock lock lock u n lock lock u n lock D4SL-N @@@@ - @ D4SL-N @@@@ - @ 4 front D4SL-N @@@@ - @ D4SL-N @@@@ - @ 4 back www.datasheet.co.kr datasheet pdf - http://www..net/
D4SL-N / D4SL-Nsk10-lk @ 24 hinged door ? if the switch is mounted too close to the hinge, the force imposed on the lock will be much larger than for locations far from the hinge and the lock may be damaged. mount the switch close to the handle. mounting appropriate tightening torque loose screws may result in malfunction. tighten the screws to the specified torques. switch and operation key mounting ? mount the switch and operation key securely to the applicable tightening torque with m4 screws. always use washers. ? the switch can be fastened more firmly by a stud (4 mm dia., 1.5 mm max height) inserted from back side at the hole of the switch. ? do not impose excessive force on the key top while the operation key is inserted into the switch body or drop the switch with the operation key inserted to avoid the deformation of the key or the breakage of the switch body. ? do not use the operation key other than dedicated omron's (D4SL-Nk @ ). otherwise switch may be damaged. ? do not use the operation key d4sl-k @ . a lock will not be closed and a machine will not be activated. ? be sure that the operation key can be inserted properly to key hole with a tolerance of 0. 8 mm. ? insert the operation key into the key hole according to the specified ?operation key insertion radius in horizontal direction?. ? when mounting at the side of switch body, mount the switch with 3 points including the head. ? attach cap heads to any operation key holes that are not being used. securing the door when the door is closed (with the operation key inserted), the operation key may exceed the set zone because of, for example, the door's own weight, machine vibration, or the door cushion rubber. secure the door with a stopper (hook) so that the operation key remains within the set zone. spacer do not remove a spacer. rotate the spacer in accordance with the switch mounting direction. use of the switch without spacer will reduce the lock strength. wiring circuit connection example ? direct opening contacts used as safety-circuit inputs are indicated with the mark. ? dc solenoids have polarity. (e1: + , e2: ? ) confirm terminal polarity before wiring. ? the current of the 24 vdc solenoid is different from when it is first turned on as to when it is in operation. to take into account possible voltage drops, it is important to apply a rated operation voltage. ? to enable the 24 vdc solenoid, it is necessary to select the appropriate power supply capacity. ? the on and off contact operation will not engage simultaneously. be sure to confirm operation under actual operating conditions. (D4SL-N @ n @@ -d @ ) (D4SL-N @ sf @ - @ ) cover mounting screw 0.4 to 0.5 n ? m operation key mounting screw 2.4 to 2. 8 n ? m (D4SL-Nk @ and -nk @ s) 0.75 to 1.15 n ? m (D4SL-Nk @ g) switch mounting screw 0.75 to 1.15 n ? m connector 1. 8 to 2.2 n ? m (except 1/2-14npt) 1.4 to 1. 8 n ? m (1/2-14npt) terminal screw * terminal block type only 0.5 to 0.6 n ? m (D4SL-N @@@@ - @@ ) 15 0.1 40 0.1 10 0.1 t w o, m4 12 0.1 or 20 0.1 t w o, m4 t w o, m4 38.7 0.1 three, m4 22 0.1 41.7 0.15 41.7 0.15 front D4SL-Nk1/-nk2 D4SL-Nk1g/-nk2g D4SL-Nk3 side t w o, m4 4 0.1 dia. 1.5 max. 22 0.1 4 0.1 dia. 1.5 max. switch mounting operation key mounting set zone (0.5 to 3 mm) operation key spacer mo u nting side e1 ( + ) e2 ( ? ) to safety circ u it to control circ u it 11 21 33 lock monitor s w itch 9 10 led 41 51 63 42 52 64 1 2 3 4 5 6 7 8 12 22 34 to control circ u it to safety circ u it door open/ closed detection s w itch e1 ( + ) e2 ( ? ) to control circ u it 21 41 33 lock monitor s w itch 9 10 63 42 22 64 1 2 3 4 5 6 7 8 34 to control circ u it to safety circ u it door open/ closed detection s w itch a n d www.datasheet.co.kr datasheet pdf - http://www..net/
D4SL-N / D4SL-Nsk10-lk @ 25 wiring precautions for D4SL-N @@@@ - @@ ? do not wire the switch while power is being supplied. doing so may result in electric shock. ? do not let particles, such as small pieces of lead wire, enter the switch body when wiring. ? do not directly wire the stranded wire to the terminal block. ? when connecting to the terminals via insulating tube and bar terminals, arrange the bar terminals so that they do not rise up onto the case or the cover. ? applicable lead wire size: awg22 to awg1 8 (0.3 to 0.75 mm 2 ). ? use lead wires of an appropriate length. not doing so may result in excess length causing the cover to rise and not fit properly. ? remove the terminal block board out of the unit to perform wiring. be sure to insert the connector properly. ? do not pull on the lead wires with excessive force. doing so may disconnect them. recommended crimp terminals wiring precautions for D4SL-N @@@@ - @@ n ? do not wire the switch while power is being supplied. doing so may result in electric shock. ? do not let particles, such as small pieces of lead wire, enter the switch body when wiring. ? applicable lead wire size: awg24 to awg22 (0.2 to 0.3 mm 2 ). do not apply a current of 2 a or more when using awg24. ? use lead wires of an appropriate length. not doing so may result in excess length causing the cover to rise and not fit properly. ? do not pull on the lead wires with excessive force. doing so may disconnect them. ? do not forcibly insert the wired socket at the cable side into the connector or D4SL-N?s conduit opening. doing so may cause cable break. be sure to insert the cable into the connector or d4sl?s conduit opening before performing wiring to the socket, or insert the cable into the connector or conduit opening from the opposite side of the socket. applicable socket for cable side processing the conduit opening ? connect a recommended connector to the opening of the conduit and tighten the connector to the proper torque. the case may be damaged if excessive tightening torque is applied. ? use the cable with the connector-specified outside diameter. ? for the 1/2-14npt conduit, mount a provided conversion adapter to use the connector above. recommended connectors ? use a connector with a screw section not exceeding 9 mm. otherwise the screws will protrude into the case interior. the connectors given in the following table have connectors with screw sections not exceeding 9 mm. use the following connectors to ensure conformance to ip67. ? use lapp connectors together with seal packing (jpk-16 for g1/ 2, or gpm20 for m20), and tighten to the applicable torque. seal packing is sold separately. ? lapp is a german manufacturer. ? ace service co. is a japanese manufacturer. manufacturer model applicable wire lead phoenix contact ai0.34- 8 tq awg22 ai0.5- 8 wh awg20 ai0.75- 8 gy awg1 8 manufacturer name model j.s.t. mfg co. housing xhp-10 contact (applicable wire lead: awg24 to awg22) sxh-001t-p0.6 30 3 mm 40 3 mm 1 3 5 7 9 2 4 6 8 10 1 3 5 7 9 2 4 6 8 10 l1 l2 l1: 14 mm max. l2: 8 mm max. 1 2 10 30 3 mm 45610 3 2 1 size manufacturer model applicable cable diameter remarks g1/2 lapp st-pf1/2 53 8 0-1002 6.0 to 12.0 mm ace service co. ls-2g 6.0 to 11.0 mm short type m20 lapp st-m20 1.5 5311-1020 7.0 to 13.0 mm 1/2- 14npt lapp st-npt1/2 5301-6030 6.0 to 12.0 mm www.datasheet.co.kr datasheet pdf - http://www..net/
D4SL-N / D4SL-Nsk10-lk @ 26 D4SL-Nsk10-lk @ ? use this product for a lightweight door (20 kg max). otherwise the product may be damaged. ? this product is for D4SL-N guard lock safety-door switch only. this product cannot be used with any other manufacturer's door switches. ? use the slide handle in the direction a or b in the following figure. ? loose screws may result in malfunction. use washers and tighten the screws to the specified torques. mount the slide base at four points with screws. adding adhesive is recommended for preventing the screws from loosening. also, when mounting the product to a door for disable-prevention purposes, purchase and use tamper-resistant screws. approriate tightening torque technical specifications ? do not store the switch where corrosive gases (e.g., h 2 s, so 2 , nh 3 , hno 3 or cl 2 ) or dust is present, or in locations subject to high temperature or humidity. ? perform maintenance inspections periodically. ? when the lockout key is attached to your wrist, be careful that the strap does not get stuck in equipment. nomenclature differences between lockout key and trapped key (reference) ? when mounting the operation key, line up the inside edges of the long operation key holes with the outer edges of the slide handle as in the following figure to ensure easy position adjustment. ? use the supplied special screws to mount the operation key and D4SL-N guard lock safety-door switch. ? to tighten the screws, use the tip of a flat-head screwdriver on the screw heads as shown in the following figure. ? the special screws cannot be removed once they are tightened. mounting of innner lever mounting method 1) detaching of mounting screw remove the handle mounting screw with torx screwdriver (t30). 2) mounting of inner lever tighten a portion of the inner lever to a suitable torque with wrench (width across flat: 10mm). ? this product is for omron, the D4SL-Nsk10 and the d4gl-sk10 only. this product cannot be used with any other products. ? do not operate the handle with the handle mounting screw removed. doing so may result in malfunction. ? be careful not to lose the spring washer and hexagonal nut when remove the handle mounting screw. (fig.1) ? loose inner lever may result in malfunction. use washers and tighten the inner lever to the specified torque. (fig.2) slide key mounting screw (m6) 6.0 to 7.0 n ? m operation key special mounting screw (screws supplied) 2.4 to 2. 8 n ? m switch special mounting screw (screws supplied) 0.75 to 1.15 n ? m inner lever 9 to 10 n ? m ambient operating temperature ? 10 to 55 c (with no icing) ambient operating humidity 95% max. mechanical durability 20,000 operations min. a b slide lock slide free slide lock slide free slide key unit d4sl- n g u ard lock safety-door s w itch release key operation key locko u t key slide handle slide base shot bolt g u ide lockout key trapped key (refer to information on the d4jl- @@@ a- @ 7- @@ ) closing the door the door cannot be closed unless the lockout key is inserted in the slide and turned. the door cannot be closed unless the trapped key is inserted in the switch and turned. opening the door the door can be opened by supplying power to the switch solenoid without operating the lockout switch. the door can never be opened without both supplying power to the switch solenoid and operating the trapped key. note: the special screws are designed so that they cannot be turned counter-clockwise using a flat-head screwdriver. handle mo u nting scre w (torx_t30/m6) spring w asher (m6) fi g .1 hexagonal n u t (m6) handle spring w asher (m6) fi g .1 tightening tor qu e inner le v er a inner le v er (m6) 9 to 10 n . m www.datasheet.co.kr datasheet pdf - http://www..net/
r ead and u nderstand this catalog please read and understand this catalog before purchasing the products. please consult your omron representative if you have an y questions or comments. warranty and limitations of liability warranty omron?s exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by omron. omron makes no warranty or representation, express or implied, regarding non-infringement, merchantability, or fitness for particular purpose of the products. any buyer or user acknowledges that the buyer or user alone has determined that the products will suitably meet the requirements of their intended use. omron disclaims all other warranties, express or implied. limitations of liability omron shall not be responsible for special, indirect, or consequential damages, loss of profits or commercial loss in any way connected with the products, whether such claim is based on contract, warranty, negligence, or strict liability. in no event shall responsibility of omron for any act exceed the individual price of the product on which liability is asserted . in no event shall omron be responsible for warranty, repair, or other claims regarding the products unless omron?s analysis confirms that the products were properly handled, stored, installed, and maintained and not subject to contamination, abuse, misuse, or inappropriate modification or repair. application considerations suitability for use omron shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of produc ts in the customer?s application or use of the product. at the customer?s request, omron will provide applicable third party certification documents identifying ratings and limitation s of use that apply to the products. this information by itself is not sufficient for a complete determination of the suitability of the products i n combination with the end product, machine, system, or other application or use. the following are some examples of applications for which particular attention must be given. this is not intended to be an exh austive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products: ? outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described i n this document. ? nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. ? systems, machines, and equipment that could present a risk to life or property. please know and observe all prohibitions of use applicable to the products. never use the products for an application involving serious risk to life or property without ensuring that the system as a whole has been designed to address the risks, and that the omron product is properly rated and installed for the intended use within the overall equipment or system. disclaimers change in specifications product specifications and accessories may be changed at any time based on improvements and other reasons. it is our practice to change model numbers when published ratings or features are changed, or when significant construction cha nges are made. however, some specifications of the product may be changed without any notice. when in doubt, special model numbers may be assi gned to fix or establish key specifications for your application on your request. please consult with your omron representative at any time to confirm actual specifications of purchased products. dimensions and weights dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown. errors and omissions the information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assum ed for clerical, typographical, or proofreading errors, or omissions. performance data performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. it may represent the result of omron?s test conditions, and the users must correlate it to actual application requirements. actual per formance is subject to the omron warranty and limitations of liability. programmable products omron shall not be responsible for the user?s programming of a programmable product, or any consequence thereof. copyright and copy permission copyright and copy permission this document shall not be copied for sales or promotions without permission. this document is protected by copyright and is intended solely for use in conjunction with the product. please notify us before copying or reproducing this document in any manner, for any other purpose. if copying or transmitting this document to another, please cop y or transmit it in its entirety. www.datasheet.co.kr datasheet pdf - http://www..net/
authorized distributor: in the interest of product impro v ement, specifications are subject to change withou t notice. cat. no. c146-e1-01 0412 (0412) ? omro n corporation 2012 all rights reser v ed. omron corporation industrial automation company regional headquarters omron europe b.v. w egalaan 67-69-2132 jd hoofddorp the n etherlands tel: (31)2356-81-300/fax: (31)2356-81-388 contact: www.ia.omron.com tokyo, japan omron asia pacific pte. ltd. n o. 438a alexandra road # 05-05/08 (lobb y 2), alexandra technopark, singapore 119967 tel: (65) 6835-3011/fax: (65) 6835-2711 omron (china) co., ltd. room 2211, bank of china to w er, 200 yin cheng zhong road, pudong ne w area, shanghai, 200120, china tel: (86) 21-5037-2222/fax: (86) 21-5037-2200 omron scientific technologies inc. 6550 dumb arton circle, fremont, ca 94555-3605 u.s.a. tel: (1) 510-608-3400/fax: (1) 510-744-1442 csm_1_1_0412 www.datasheet.co.kr datasheet pdf - http://www..net/


▲Up To Search▲   

 
Price & Availability of D4SL-N

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X